MCP HeartbeatTHE MCP OBSERVATORY
Public workspace

Explore

Evidence for your next connection.

Independent measurements of remote MCP servers. Every observation has a timestamp.

Read-only probes

MCP server · Code & DevOps

uniwire

Electrical single-line and multi-line diagrams: build, check (NF C 15-100, IEC 60364), draw, PDF.

Checks passed
14 / 22

0 failed · 8 not measured

Median response
362 ms

Median of successful probes over 7 days

30-day uptime
Not measured

Share of countable probes over 30 days, including daily rollups. Auth challenges are excluded.

Discovered tools
14

Tool definitions returned by this server

Independent monitoring

Health & checks

Status history

Outdated check

Last connection measurement is over 24 hours old. Current availability is unknown.

Last checked
Check summary by test group
Test areaPassedFailedUnmeasured
ConnectionCan a client connect and discover tools?
500
Reliability & speedDoes it respond consistently and quickly?
004
Access & authenticationWhat is required to use this server?
102
Tool qualityAre the tool definitions usable by an agent?
400
Publisher identityCan the publisher be traced to its source?
402

Unmeasured means there is not enough evidence to decide. How these checks work

Inspect individual checks 22 recorded

Core

  • Pass
    Reachable

    Latest probe returned HTTP 200 in 362 ms.

  • Pass
    Valid handshake

    protocolVersion 2025-11-25, serverInfo.name uniwire.

  • Pass
    Lists tools

    tools/list returned 14 tools.

  • Pass
    Current protocol

    Negotiated 2025-11-25. The bar is 2025-06-18 or newer.

  • Pass
    HTTPS

    The endpoint URL is https.

Performance

  • Not measured
    Fast (p50)

    Median latency 362 ms over 1 samples in 7 days. The bar is 1000 ms. Need at least 5 samples.

  • Not measured
    Consistent (p95)

    95th percentile 362 ms over 1 samples in 7 days. The bar is 3000 ms. Need at least 20 samples.

  • Not measured
    Reliable (uptime)

    1 of 1 attempts returned a tool list in 30 days (100%). The bar is 99%. Need at least 30 samples.

  • Not measured
    Stable tool list

    Fewer than two successful probes in 30 days, so tool-list stability is not measured.

Access

  • Pass
    Open access

    tools/list succeeded with no credential, and the record declares none.

  • Not measured
    Standard auth

    Auth is not required, so the OAuth metadata check does not apply.

  • Not measured
    Free tier cited

    No publisher quote has been checked.

Tools

  • Pass
    Tools described

    Every tool description is at least 20 characters.

  • Pass
    Valid input schemas

    Every inputSchema is a JSON Schema object.

  • Pass
    Parameters documented

    29 of 29 parameters have a description (100%). The bar is 80%.

  • Pass
    Safety hints

    Every tool sets readOnlyHint or destructiveHint.

Publisher

  • Pass
    Verified namespace

    Listed in the Official MCP Registry.

  • Not measured
    Website matches publisher

    This namespace is not a reverse domain, so the website comparison does not apply.

  • Pass
    Source repo linked

    A repository URL is on file.

  • Pass
    Repo owner matches

    The GitHub repository owner matches the namespace login.

  • Pass
    Recently updated

    Updated 2026-11-02T12:23:15.777765Z, within 180 days.

  • Not measured
    Open-source licence

    The GitHub licence lookup has not returned an OSI result yet.

Start using uniwire

Connect to this server

Choose your client, copy the configuration, then enable the server in your client’s MCP settings.

Run this command in your terminal, then restart Claude Code.

Claude Code

claude mcp add --transport http uniwire https://mcp.uniwire.sh/mcp

Capabilities

Tools 14

apply_patch

Edit an electrical diagram by node id (change a rating, add a circuit, move a load...) and return the new document. ops (applied in order): {"op":"set","id":ID,"path":"in_A","value":20} (null value removes; no id = document root, e.g. path "installation.earthing"); {"op":"add","parent":ID,"node":{...},"index":0} (or "at":"sources"); {"op":"remove","id":ID}; {"op":"move","id":ID,"parent":ID,"index":0}; {"op":"rename","id":ID,"new_id":NEW}; {"op":"link","link":{"kind":"control","from":ID,"to":ID}}; {"op":"unlink","id":LINK_ID} or {"op":"unlink","from":ID,"to":ID,"kind":K}. On failure returns ok=false and errors naming the failing op index (null = validation of the result).

Discovered
bom

Compute the bill of materials (nomenclature) of an electrical installation from its document: one row per manufacturer / part number for the nodes with a product reference, then one row per kind of equipment without a reference (type and main characteristics in 'spec', e.g. 'C16 1P+N') and per kind of cable (total length in 'length_m'), with quantities and the reference designations involved. Use it to prepare a quote or an order; wiring gives the wire list and cable schedule.

Discovered
check

Check an electrical installation (single-line diagram, panel, schéma unifilaire, tableau électrique): validates the document, then applies the rule profiles (NF C 15-100 'nfc15100', French grid connection 'enedis', IEC 60364 'iec60364', PLC; default: the document's 'profiles'; 'core' always applies): breaker ratings against cable sections, RCDs, circuits per protection, selectivity... Returns findings (level error/warning/info, rule, node id, message, source), a summary, 'scope' (what the checks cover and do not cover: automatic checks of the document data, not a conformity certificate), viewer_url (the document in the uniwire web editor: drawing, findings, downloads) and pdf_url (the PDF drawn by uniwire).

Discovered
describe

Return a text outline of an electrical diagram: installation, full tree of the panel with stable ids, ratings and cables, links, interlocks, boards and findings summary. Use it to read a document and find the node ids before apply_patch.

Discovered
get_example

Return an example installation document by name. Use it as a starting point for a similar installation, then edit it with apply_patch; list_examples gives the names.

Discovered
get_reference_card

Return the reference card of the uniwire format for electrical diagrams: document skeleton, node types (breakers, RCDs, cables, loads, transformers, PV...) and their fields, enums, links, pitfalls, examples. Read it once before writing a document; type_info gives the fields of one type in detail.

Discovered
list_examples

List the 53 example installations (dwellings, shops, offices, workshops, PV, EV charging, UPS, MV/LV substations, PLCs): name, title, language, profiles, earthing, system.

Discovered
list_types

List the node types of the format (type, category, label), optionally for one category. Use it to find the type name of a device or load before writing a node; type_info then gives its fields.

Discovered
normalize

Return the resolved form of a document: templates ('use') applied, every node and link id assigned, numbers in canonical form. Use it to read a document exactly as the rules and drawings see it, or to get stable ids before apply_patch; it does not apply the electrical rules (see check).

Discovered
render

Draw the electrical diagram (schéma unifilaire / multifilaire). kind: 'single-line' or 'multi-line'; view: a view id of the document (e.g. a wire-marking view). format 'svg' returns the SVG text of every sheet (or of 'sheet', numbered from 1); 'pdf' writes to 'path' if given, else returns base64 (requires the uniwire[pdf] extra); on the hosted server it returns pdf_url (the PDF drawn by uniwire) instead. color: 'none' | 'conductors' | 'phase' | 'source' | 'status' | 'voltage' (adds a legend); conductor_colors: 'iec' (IEC 60445) | 'us'.

Discovered
type_info

Return every field of one node type with its description, unit and allowed values (enums). Use it before writing or editing a node of that type; list_types gives the type names.

Discovered
validate

Validate a uniwire document (electrical diagram as JSON) against the format only: structure, types, ids, references and links, without the electrical rules (use check for those). Returns valid + issues, each naming the node id and field when possible, plus viewer_url (the document in the uniwire web editor) and pdf_url (the PDF drawn by uniwire).

Discovered
viewer_link

Links to a document: viewer_url opens it in the uniwire web editor (drawing, single-line and multi-line, rule findings, PDF and SVG downloads, nothing to install); pdf_url is the PDF drawn by uniwire. On the hosted server the document is kept 30 days so that the short links open it (anyone with a link can open it); elsewhere it travels in the link (after '#') and is stored nowhere.

Discovered
wiring

Wiring exports of an installation as rows with stable column names (repérage des fils, carnet de câbles): what='markers' (one row per wire end, for label printers), 'wires' (wire list) or 'cables' (cable schedule). Marks follow the wire_marking rules of the view (id), by default the first view that declares them.

Discovered

Recent measurements

Probe history

View status
Latest stored probes. Raw probe rows are kept for 14 days.
CheckedResultResponseTools
Connected362 ms14