MCP HeartbeatTHE MCP OBSERVATORY
Public workspace

Explore

Evidence for your next connection.

Independent measurements of remote MCP servers. Every observation has a timestamp.

Read-only probes

MCP server · Code & DevOps

Emission Factors

Keyless US grid carbon + power cost by ZIP: eGRID Scope 2, Scope 1 fuels, site ranking, clean hours

Checks passed
15 / 22

0 failed · 7 not measured

Median response
431 ms

Median of successful probes over 7 days

30-day uptime
Not measured

Share of countable probes over 30 days, including daily rollups. Auth challenges are excluded.

Discovered tools
11

Tool definitions returned by this server

Independent monitoring

Health & checks

Status history

Responded

The server completed its last measured handshake. This is an observation, not a guarantee.

Last checked
Check summary by test group
Test areaPassedFailedUnmeasured
ConnectionCan a client connect and discover tools?
500
Reliability & speedDoes it respond consistently and quickly?
103
Access & authenticationWhat is required to use this server?
102
Tool qualityAre the tool definitions usable by an agent?
400
Publisher identityCan the publisher be traced to its source?
402

Unmeasured means there is not enough evidence to decide. How these checks work

Inspect individual checks 22 recorded

Core

  • Pass
    Reachable

    Latest probe returned HTTP 200 in 429 ms.

  • Pass
    Valid handshake

    protocolVersion 2025-06-18, serverInfo.name emission-factors.

  • Pass
    Lists tools

    tools/list returned 11 tools.

  • Pass
    Current protocol

    Negotiated 2025-06-18. The bar is 2025-06-18 or newer.

  • Pass
    HTTPS

    The endpoint URL is https.

Performance

  • Not measured
    Fast (p50)

    Median latency 431 ms over 2 samples in 7 days. The bar is 1000 ms. Need at least 5 samples.

  • Not measured
    Consistent (p95)

    95th percentile 433 ms over 2 samples in 7 days. The bar is 3000 ms. Need at least 20 samples.

  • Not measured
    Reliable (uptime)

    2 of 2 attempts returned a tool list in 30 days (100%). The bar is 99%. Need at least 30 samples.

  • Pass
    Stable tool list

    No tool was removed and no required parameter was added in the last 30 days.

Access

  • Pass
    Open access

    tools/list succeeded with no credential, and the record declares none.

  • Not measured
    Standard auth

    Auth is not required, so the OAuth metadata check does not apply.

  • Not measured
    Free tier cited

    No publisher quote has been checked.

Tools

  • Pass
    Tools described

    Every tool description is at least 20 characters.

  • Pass
    Valid input schemas

    Every inputSchema is a JSON Schema object.

  • Pass
    Parameters documented

    36 of 37 parameters have a description (97%). The bar is 80%.

  • Pass
    Safety hints

    Every tool sets readOnlyHint or destructiveHint.

Publisher

  • Pass
    Verified namespace

    Listed in the Official MCP Registry.

  • Not measured
    Website matches publisher

    This namespace is not a reverse domain, so the website comparison does not apply.

  • Pass
    Source repo linked

    A repository URL is on file.

  • Pass
    Repo owner matches

    The GitHub repository owner matches the namespace login.

  • Pass
    Recently updated

    Updated 2026-10-19T02:46:15.520086Z, within 180 days.

  • Not measured
    Open-source licence

    The GitHub licence lookup has not returned an OSI result yet.

Start using Emission Factors

Connect to this server

Choose your client, copy the configuration, then enable the server in your client’s MCP settings.

Run this command in your terminal, then restart Claude Code.

Claude Code

claude mcp add --transport http emission-factors https://emission-factors.com/mcp

Capabilities

Tools 11

calculate_emissions

Calculate Scope 2 CO2e for a facility from its ZIP and kWh, using both GHG Protocol methods: location-based (eGRID subregion rate) and market-based (Green-e residual mix applied to kWh not covered by RECs, PPAs or green tariffs). Returns kg CO2e for each method with the factors used.

Discovered
calculate_fuel_emissions

Calculate Scope 1 stationary-combustion emissions (CO2, CH4, N2O and CO2e) for fuels burned on site, using the GHG Emission Factors Hub 2026 (Cornerstone, successor to EPA's Hub; IPCC AR6 GWPs) by default, or EPA's 2025 edition (AR5) with edition=2025. Pass one or more items with fuel, quantity and unit, e.g. natural gas in therms/ccf/mcf/scf, propane/diesel/heating oil in gallons, coal in short tons. Biomass CO2 is reported separately (biogenic). Stationary sources only: for vehicle fuel the CO2 per gallon is the same, but CH4/N2O factors differ and are not included. Returns per-item and total CO2e. Pair with calculate_emissions for a facility's electricity (Scope 2).

Discovered
cleanest_hours

Find the cleanest (lowest grid carbon) contiguous window of N hours in the day to run a flexible load (batch jobs, EV charging, pumping, HVAC pre-cooling) at a US ZIP code or balancing authority. Based on the hour-of-day pattern of the last 7 days (168 hours) of EIA-930 data, in local time. Returns the cleanest and dirtiest windows, % saved vs the daily average, and all hours ranked; between limits the windows to given local hours (e.g. overnight). A scheduling guide from recent history, not a forecast.

Discovered
compare_sites

Compare and rank 2-25 candidate US sites (ZIP codes) for a facility, data center or EV/flexible load on grid carbon and electricity cost in one call. Per site: eGRID CO2e kg/kWh (location-based), Green-e residual mix (market-based), carbon-free %, $/kWh for the sector (the state's latest full-year average, EIA-861 annual; the ZIP's own 2023 utility average is shown as a reference), and the cleanest daily window from the 7-day hourly profile of its balancing authority, in the ZIP's local time. lowest_cost and best_combined are null unless every site has a rate. With annual_kwh, also annual tCO2e and cost. Returns competition ranks by carbon, cost and combined, gap percentages, and best_* = null with *_tied lists when sites tie.

Discovered
electricity_rate

Get the latest monthly average retail electricity rate ($/kWh and cents/kWh) for any US ZIP code, broken out by sector (residential, commercial, industrial, etc.). Data is state-level from EIA Form 861 - a ballpark, not utility- or ZIP-specific tariffs (use utility_tariff for those).

Discovered
hourly_intensity

Get hourly grid carbon intensity (kg CO2e per kWh) for any US ZIP code, derived from EIA-930 hourly fuel-mix data. Data lags up to about a day (not real-time). Returns time series with per-hour fuel mix, total generation, and carbon intensity. For timing and analysis (demand response, load shifting, grid patterns), not inventory reporting: it uses fixed per-fuel combustion factors on in-BA generation (no imports), so its values don't match eGRID's annual factors. For live or forecast intensity, WattTime or Electricity Maps are better options.

Discovered
lookup_batch

Look up emission factors for up to 100 ZIP codes in one call (split longer lists). Returns one compact row per ZIP - subregion, CO2e kg/kWh (location-based), residual mix (market-based), carbon-free %, utility - unless full is true, which returns every field (about 2 KB per ZIP).

Discovered
lookup_by_coordinates

Look up emission factors by latitude/longitude. Uses US Census Geocoder to resolve to ZIP first, then returns the same data as lookup_emission_factor. Useful when you have a facility address or lat/lon but no ZIP.

Discovered
lookup_emission_factor

Look up EPA eGRID electricity emission factors for a US ZIP code. Returns CO2e (kg/kWh and lb/MWh), CO2, CH4, N2O, NOx, SO2, non-baseload rate, carbon-free %, generation mix (coal/gas/nuclear/hydro/wind/solar etc.), eGRID subregion code, the data year, and the Green-e residual mix rate (the market-based Scope 2 factor). For Scope 2 emissions from a kWh total, use calculate_emissions, which does the arithmetic for both methods.

Discovered
plant_emissions

Get emissions from EPA Clean Air Markets Division (CAMD) for a specific US power plant or a state: fossil units over 25 MW reporting to the Acid Rain Program and CSAPR. Per facility returns total CO2 (short tons), gross generation (MWh), heat input (mmBtu), NOx and SO2 (lb), primary fuel type, operating hours, and derived emissions rate (kg CO2/MWh). CAMD publishes by quarter, so the default window is the last 7 days of the latest published quarter (latest_published_date in the response); later dates are not available yet. Default output is a per-facility summary from daily data; format=hourly returns unit-hour records for small windows. Use for plant-specific carbon accounting, state-level fossil emissions and "dirtiest plants in [state]" queries.

Discovered
utility_tariff

Get the actual utility-specific electricity rate (not state average) for a US ZIP code or named utility. Returns the current default tariff with effective rate ($/kWh), fixed monthly charge, tier count, TOU indicator, and effective date. Data source: OpenEI URDB (NREL-hosted). With a ZIP, matches the ZIP's utility by EIA ID. Returns currently-effective tariffs; when URDB has none flagged as default (common for Commercial/Industrial) it returns the most recent ones and says so in warnings, including when the newest available tariff has expired. Does not cover Texas retail electric providers (deregulated market) - use electricity_rate there.

Discovered

Recent measurements

Probe history

View status
Latest stored probes. Raw probe rows are kept for 14 days.
CheckedResultResponseTools
Connected429 ms11
Connected433 ms11