MCP HeartbeatTHE MCP OBSERVATORY
Public workspace

Explore

Evidence for your next connection.

Independent measurements of remote MCP servers. Every observation has a timestamp.

Read-only probes

MCP server · Code & DevOps

VoltPlan Wiring Diagrams

Generate 12V/24V/48V wiring diagrams and size wires, fuses, batteries, solar, and inverters.

Checks passed
14 / 22

0 failed · 8 not measured

Median response
130 ms

Median of successful probes over 7 days

30-day uptime
Not measured

Share of countable probes over 30 days, including daily rollups. Auth challenges are excluded.

Discovered tools
9

Tool definitions returned by this server

Independent monitoring

Health & checks

Status history

Outdated check

Last connection measurement is over 24 hours old. Current availability is unknown.

Last checked
Check summary by test group
Test areaPassedFailedUnmeasured
ConnectionCan a client connect and discover tools?
500
Reliability & speedDoes it respond consistently and quickly?
004
Access & authenticationWhat is required to use this server?
102
Tool qualityAre the tool definitions usable by an agent?
400
Publisher identityCan the publisher be traced to its source?
402

Unmeasured means there is not enough evidence to decide. How these checks work

Inspect individual checks 22 recorded

Core

  • Pass
    Reachable

    Latest probe returned HTTP 200 in 130 ms.

  • Pass
    Valid handshake

    protocolVersion 2025-11-25, serverInfo.name wiring-diagram-mcp.

  • Pass
    Lists tools

    tools/list returned 9 tools.

  • Pass
    Current protocol

    Negotiated 2025-11-25. The bar is 2025-06-18 or newer.

  • Pass
    HTTPS

    The endpoint URL is https.

Performance

  • Not measured
    Fast (p50)

    Median latency 130 ms over 1 samples in 7 days. The bar is 1000 ms. Need at least 5 samples.

  • Not measured
    Consistent (p95)

    95th percentile 130 ms over 1 samples in 7 days. The bar is 3000 ms. Need at least 20 samples.

  • Not measured
    Reliable (uptime)

    1 of 1 attempts returned a tool list in 30 days (100%). The bar is 99%. Need at least 30 samples.

  • Not measured
    Stable tool list

    Fewer than two successful probes in 30 days, so tool-list stability is not measured.

Access

  • Pass
    Open access

    tools/list succeeded with no credential, and the record declares none.

  • Not measured
    Standard auth

    Auth is not required, so the OAuth metadata check does not apply.

  • Not measured
    Free tier cited

    No publisher quote has been checked.

Tools

  • Pass
    Tools described

    Every tool description is at least 20 characters.

  • Pass
    Valid input schemas

    Every inputSchema is a JSON Schema object.

  • Pass
    Parameters documented

    35 of 35 parameters have a description (100%). The bar is 80%.

  • Pass
    Safety hints

    Every tool sets readOnlyHint or destructiveHint.

Publisher

  • Pass
    Verified namespace

    Listed in the Official MCP Registry.

  • Not measured
    Website matches publisher

    This namespace is not a reverse domain, so the website comparison does not apply.

  • Pass
    Source repo linked

    A repository URL is on file.

  • Pass
    Repo owner matches

    The GitHub repository owner matches the namespace login.

  • Pass
    Recently updated

    Updated 2026-10-26T21:57:52.431087Z, within 180 days.

  • Not measured
    Open-source licence

    The GitHub licence lookup has not returned an OSI result yet.

Start using VoltPlan Wiring Diagrams

Connect to this server

Choose your client, copy the configuration, then enable the server in your client’s MCP settings.

Run this command in your terminal, then restart Claude Code.

Claude Code

claude mcp add --transport http voltplan-wiring-diagrams https://mcp.voltplan.app/mcp

Capabilities

Tools 9

calculate_battery_bank

Calculate the recommended battery bank size based on daily energy consumption. Accounts for days of autonomy (how many days without charging) and depth of discharge. Returns required capacity, number of batteries, and wiring configuration.

Discovered
calculate_battery_config

Determine how to arrange batteries in series and/or parallel to achieve a target voltage and capacity. Returns the number of batteries needed, the wiring configuration (e.g. 2S3P), and step-by-step wiring instructions.

Discovered
calculate_charging_time

Estimate how long it takes to charge a battery bank from a given state of charge to a target level. Accounts for the bulk charging phase (constant current, up to ~80% SoC) and the slower absorption phase (tapering current, 80-100% SoC). Works for any charging source: solar, shore power, alternator.

Discovered
calculate_inverter_size

Calculate the recommended inverter size for running AC loads from a DC battery system. Accounts for continuous power, startup surge power (motors typically surge 2-3x), and includes a 25% headroom for the continuous rating. Returns the recommended inverter wattage and the DC current draw at system voltage.

Discovered
calculate_power_budget

Calculate total daily energy consumption from a list of electrical loads. Each load specifies its power draw, how many hours per day it runs, and quantity. Returns total daily energy (Wh and Ah), peak power draw, and average power. This is typically the first step in sizing a battery bank and solar system.

Discovered
calculate_solar_size

Calculate the required solar panel wattage to cover daily energy consumption. Accounts for peak sun hours at the location and system efficiency losses (MPPT conversion, wiring, temperature derating). Returns required wattage and common panel configurations.

Discovered
calculate_wire_gauge

Calculate the recommended wire gauge / cable cross-section for a DC circuit. Considers both ampacity (current carrying capacity) and voltage drop to recommend the optimal cable size. Also returns total resistance, power loss, and a fuse recommendation. Supports copper conductors from 0.75 mm² (18 AWG) to 240 mm² (300 MCM).

Discovered
generate_wiring_diagram

Generate an electrical wiring diagram for campers, boats, or off-grid setups. Returns the schematic as an image (batteries, chargers, protection components, loads) and a link that opens it in the VoltPlan editor to refine, save and turn into a shopping list. Protection components (shunt, main switch, low-voltage cutoff) are auto-generated when both batteries and loads are provided. Show the user the editor link.

Discovered
list_component_types

List all available component types and example configurations for building wiring diagrams. Use this to understand what parameters are needed before calling generate_wiring_diagram.

Discovered

Recent measurements

Probe history

View status
Latest stored probes. Raw probe rows are kept for 14 days.
CheckedResultResponseTools
Connected130 ms9