Arabic Excel templates and 23 calculators (VAT, BMI, gold zakat...). No key, nothing stored.
- Passed: Handshake
- Passed: Tools listed
- Passed: Updated recently
Median latency 79 ms · Last checked
Explore
Evidence for your next connection.
Independent measurements of remote MCP servers. Every observation has a timestamp.
Read-only probesMCP server · File & docs
Verbex Lab Tools: deterministic wet-lab calculators and lab document templates, each checked.
2 failed · 8 not measured
Median of successful probes over 7 days
Share of countable probes over 30 days, including daily rollups. Auth challenges are excluded.
Tool definitions returned by this server
Independent monitoring
Outdated check
Last connection measurement is over 24 hours old. Current availability is unknown.
Last checked| Test area | Passed | Failed | Unmeasured |
|---|---|---|---|
ConnectionCan a client connect and discover tools? | 5 | 0 | 0 |
Reliability & speedDoes it respond consistently and quickly? | 0 | 0 | 4 |
Access & authenticationWhat is required to use this server? | 1 | 0 | 2 |
Tool qualityAre the tool definitions usable by an agent? | 3 | 1 | 0 |
Publisher identityCan the publisher be traced to its source? | 3 | 1 | 2 |
Unmeasured means there is not enough evidence to decide. How these checks work
Start using Verbex Lab Tools
Choose your client, copy the configuration, then enable the server in your client’s MCP settings.
Run this command in your terminal, then restart Claude Code.
Claude Code
claude mcp add --transport http verbex-lab-tools https://www.verbalexperiment.com/mcpCapabilities
Build an electronic lab notebook (ELN) entry template for an experiment: objective, materials, procedure, observations and conclusion sections from a preset or custom list, optionally with timestamp fields and voice-capture prompts. Returns Markdown and HTML.
DiscoveredGet the full text of a search result by id, as Markdown. Guides come with a short summary; templates include the blank template, a worked example where there is one, and a link to the editable Word or Excel file. Calculators return the method, the input fields and a worked example computed by the calculator.
DiscoveredPlan a lipid nanoparticle (LNP) formulation for RNA: from RNA mass, N/P ratio and lipid mol% (e.g. ionizable lipid/DSPC/cholesterol/PEG-lipid 50/10/38.5/1.5), calculate moles, mass and stock volume of every lipid, the ethanol and aqueous phase volumes at the chosen mixing ratio (default 3:1), and final RNA concentration, ethanol fraction and lipid:RNA ratio. Molecular weights must come from the user or certificates of analysis.
DiscoveredTurn text read from a reagent bottle or kit label (OCR or typed) into structured fields such as product name, catalog number, lot, expiry, concentration and storage. Parses the provided text only; send the label text, not an image.
DiscoveredUse when someone sets up a PCR or qPCR reaction mix for several wells. Calculates volume of each component per reaction and for the whole mix with excess, with water filling the remaining volume. Give each component a stock and final concentration (molar, ng/µL, x buffer, %), an amount per reaction (e.g. 1.25 U polymerase from 5 U/µL, 10 ng template from ng/µL), or a fixed volume. Template can be added per well separately. Do not list water; it is calculated.
DiscoveredUse when someone lays out a multiwell plate (ELISA, qPCR, cell or compound assays). Lays out a 6, 12, 24, 48, 96 or 384-well plate: standards, samples, controls and blanks with replicates, filled by row or column, optionally leaving edge wells empty and keeping replicate sets together. Returns a grid with a key and a well-by-well list.
DiscoveredBuild a structured lab protocol (purpose, materials, procedure, critical steps, acceptance criteria and more) for a protocol title, using a preset or custom sections. Returns Markdown and HTML ready to fill in or print.
DiscoveredSearch Verbex guides and templates: practical guides (protocols and SOPs, lab notebooks, inventory, data integrity and GLP, equipment records, bench calculations) and the 16 lab documentation templates. Returns ids to pass to fetch, with titles and urls to cite. Not for calculations: to compute a mass, volume, dilution, master mix, LNP formulation or plate map, call that calculator directly.
DiscoveredUse for any serial dilution (standard curves, titrations, dose series). Plans transfer and diluent volume per tube and the resulting concentration at each step, from a stock concentration, a constant dilution factor, the number of tubes and the final volume per tube.
DiscoveredUse when someone asks how much solid to weigh for a molar solution (how many grams for X mM in Y mL, making up a buffer or salt solution), or how much stock to dilute to a target concentration (C1V1). mode "solid": mass of solid to weigh from molecular weight, target concentration and final volume. mode "stock": C1V1 = C2V2 dilution from a stock, solving for stockVolume, stockConcentration, targetConcentration or finalVolume. Returns the primary result, a step summary, warnings and safety notes.
DiscoveredRecent measurements
| Checked | Result | Response | Tools |
|---|---|---|---|
| Connected | 613 ms | 10 |