deepdna.aiVerified
Pharmacogenomics for AI agents: cited drug–gene, gene and rsID lookups plus a medication screen.
HealthcareData access / search
- Passed: Handshake
- Passed: Tools listed
- Passed: Updated recently
Median latency 1277 ms · Last checked
Explore
Evidence for your next connection.
Independent measurements of remote MCP servers. Every observation has a timestamp.
Read-only probesMCP server · Data access / search
Human hepatic clearance from in-vitro CLint, with the error band measured on known drugs.
1 failed · 8 not measured
Median of successful probes over 7 days
Share of countable probes over 30 days, including daily rollups. Auth challenges are excluded.
Tool definitions returned by this server
Independent monitoring
Outdated check
Last connection measurement is over 24 hours old. Current availability is unknown.
Last checked| Test area | Passed | Failed | Unmeasured |
|---|---|---|---|
ConnectionCan a client connect and discover tools? | 5 | 0 | 0 |
Reliability & speedDoes it respond consistently and quickly? | 0 | 0 | 4 |
Access & authenticationWhat is required to use this server? | 1 | 0 | 2 |
Tool qualityAre the tool definitions usable by an agent? | 4 | 0 | 0 |
Publisher identityCan the publisher be traced to its source? | 3 | 1 | 2 |
Unmeasured means there is not enough evidence to decide. How these checks work
Start using ivive.app
Choose your client, copy the configuration, then enable the server in your client’s MCP settings.
Run this command in your terminal, then restart Claude Code.
Claude Code
claude mcp add --transport http ivive-app https://api.ivive.app/mcp/Capabilities
Hepatic and plasma clearance from in-vitro CLint, fu,mic and fu,p (IVIVE), with the observed-CL band and applicability warnings. If fu,p or fu,mic came from predict_inputs, tell the user the result rests on predicted inputs.
DiscoveredHow far plasma CL moves as each input is varied over a range, e.g. a predicted fu,p over its 50% range.
DiscoveredPredict fu,p and fu,inc from a SMILES, with structure-only human CL and Vss as second opinions. Predictions, not measurements; check the applicability verdict.
DiscoveredPredict human plasma CL from observed animal in-vivo CL (rat, dog, monkey), every applicable method with its measured error. Observed animal CL only, never predicted.
DiscoveredNearest reference drugs to a SMILES (Tanimoto, Morgan radius 2), each with measured human plasma CL and the CL IVIVE predicted from its measured inputs. Use it to judge how far to trust calc_clhep for this chemotype: if IVIVE missed on the neighbours, expect it to miss here. Returns neighbours only, not a prediction for the query.
DiscoveredThe in-vitro CLint an assay must read for a compound to reach a target plasma clearance (mL/min/kg): calc_clhep run backwards, e.g. to set a CLint cut-off for a screening cascade. Needs fu,mic and fu,p; refuses a target at or above the liver blood flow ceiling and returns that ceiling. Uncorrected IVIVE, so no error band.
DiscoveredRecent measurements
| Checked | Result | Response | Tools |
|---|---|---|---|
| Connected | 111 ms | 6 |